FCC Expansion Joints for refinery in Northern Europe
On this occasion, our client has given us the order for the design, manufacture, testing and shipment of three FCC Expansion Joints for a refinery in the north of Europe.
Highlights of the Expansion Joints supplied:
Applicable Standards
- EJMA 10th Edition
- B31.3 Ed. 2016
- ASME VIII Div.1 Ed.2019
- ASME II Ed. 2019
- UOP Specifications
Two ply bellows testable system
Double bellows in SB443 N06626 (alloy 625 LCF)
Telescopic Inner Sleeves in A/SA240 304H Class
Bellows internal packed insulation
Pipes and cones in A/SA240 304H Class 2
Pantographic system in SA516Gr.70 MT
Thermocouples K type
MACOGA FCCU EXPANSION JOINT
DN 1500 - Bellows Design Conditions: 0.35 barg and 450 ºC, LMDMT: -29°C
MACOGA FCCU EXPANSION JOINTS
DN 1050 - Bellows Design Conditions: 3.11 barg and 450 ºC, LMDMT: -10°C;
MACOGA FCCU EXPANSION JOINTS
DN 600 - Bellows Design Conditions: 3.11 barg and 450 ºC, LMDMT: -10°C;