Large Engineered FCC Expansion Joints for a Petrochemical plant in the Far East
We have successfully designed, manufactured, tested and shipped three 78” FCCU Expansion Joints for an oil refinery in the Far East.
The client produces oil products, such as gasoline, naphtha, diesel, jet fuel, kerosene, fuel oil and liquefied petroleum gas (LPG) and petrochemical basic materials, such as ethylene, propylene and butadiene, etc.
The Expansion Joints have been designed as per UOP Standards and they will be installed at the refinery’s Fluid Catalytic Cracking Unit (FCCU).
Main mechanical design and constructive parameters and features are:
Design Codes
- EJMA latest edition
- ASME Code
- UOP Standards
Type Tied Universal ND 78” (DN2000) Hot Wall
- Overall connecting length: 7040 mm (23 ft)
- Bellows in Alloy 625 Gr.1 (2.4856) UNS N06625
- 2 ply testable system with leak detectors
- Pipes A/SA 182 F304H
- Design pressure: 3.2 barg
- Bellows Design Temperature: +538°C
- Pipe-Line Design Temperature: +746 °C
- Medium: Flue Gas
Type Tied Universal ND 78” (DN2000) Hot Wall
- Overall connecting length: 7086 mm (23.24 ft)
- Bellows in Alloy 625 Gr.1 (2.4856) UNS N06625
- 2 ply testable system with leak detectors
- Pipes A/SA 182 F304H
- Design pressure: 3.2 barg
- Bellows Design Temperature: +538°C
- Pipe-Line Design Temperature: +746 °C
- Medium: Flue Gas
In-Line Pressure Balanced ND 78” (DN2000) Hot Wall
- Overall connecting length: 2500 mm (98.42”)
- Bellows in Alloy 625 Gr.1 (2.4856) UNS N06625
- 2 ply testable system with leak detectors
- Pipes A/SA 182 F304H
- Design pressure: 3.2 barg
- Bellows Design Temperature: +538°C
- Pipe-Line Design Temperature: +746 °C
- Medium: Flue Gas